Products

Categories

Critical Care

CENTUM DUO

CENTUM DUO

Double Lumen Central Venous Catheter (Seldinger technique)

Centrally inserted, double lumen central venous catheter

  • For administration of hyperosmolar solutions, measuring CVP, haemodialysis,
    plasmapheresis, rapid infusion of fluid among other uses.
  • Centum provides the benefit of polyurethane catheter which is soft, kink
    resistant, extremely biocompatible with excellent wear properties and elastic
    memory
  • Two separate non-communicating vascular access lumens within a single
    catheter body
  • Proximal lumen for blood sampling, medications and blood administration
  • Distal lumen for CVP monitoring, blood administration and medication
  • Reduces the necessity for multiple venipunctures
  • Exit ports of inspanidual lumens are separated by appropriate distance in
    proportion to the catheter’s French size
  • Coaxial catheter design maximizes inner diameter of central lumen for high
    flow capacity
  • Disposable, sterile and non-pyrogenic
  • Sealed blister packing
Sizes and technical specifications

Size catheter length Flow rate
(ml/min)
7.0Fr Double Lumen Proximal 16G
Distal 16G
2.5mm 15cm 62
7.0Fr Double Lumen Proximal 16G
Distal 16G
2.5mm 20cm 62
7.0Fr Double Lumen Proximal 16G
Distal 16G
2.5mm 30cm 45
CENTUM TRIO

CENTUM TRIO

Triple Lumen Central Venous Catheter (Seldinger technique)

Centrally inserted, triple lumen central venous catheter

  • For administration of hyperosmolar solutions, measuring CVP,
    haemodialysis, plasmapheresis, rapid infusion of fluid among other uses
  • Centum provides the benefit of polyurethane catheter which is soft, kink
    resistant, extremely biocompatible with excellent wear properties and
    elastic memory
  • Three separate non-communicating vascular access lumens within a single
    catheter body
  • Proximal lumen for blood sampling, medications and blood administration
  • Distal lumen for CVP monitoring, blood administration, medications
  • Medial lumen exclusively for total parenteral nutrition
  • Reduces the necessity for multiple venipunctures
  • Exit ports of inspanidual lumens are separated by appropriate distance in
    proportion to the catheter’s french size
  • Coaxial catheter design maximizes inner diameter of central lumen for high
    flow capacity
  • Disposable, sterile and non-pyrogenic
  • Sealed blister packing
Size Catheter Length Flow rate
(ml/min)
7.0Fr Triple Lumen Distal 16G
Proximal 18G
Medial 18G
2.5mm 15cm 62
27
27
7.0Fr Triple Lumen Distal 16G
Proximal 18G
Medial 18G
2.5mm 20cm 51
25
24
7.0Fr Triple Lumen Distal 16G
Proximal 18G
Medial 18G
2.5mm 30cm 40
18
19