Aqua Soft Up Flow Water Softener, softens the hard water and provides good quality water for use in laboratories and in various chemical, pharmaceutical and food industries. Aqua soft series comes in different models to suit every customer's need.
Features :
Specifications :
Model No. | Resin Qty (lit) | Max Flow Rate(lit/hr) | Output bet. Reg .(lts) | Min pr.(kg/cm2) | Max pr.(kg/cm2) |
AS 600 | 5 | 300 | 2500 | 0.5 | 2.5 |
AS 1200 | 10 | 600 | 5000 | 2.0 | 3.5 |
AS 1.8K | 15 | 900 | 8000 | 2.0 | 3.5 |
AS 3.6K | 30 | 1500 | 16000 | 2.0 | 3.5 |
AS 6.6K | 55 | 3000 | 30000 | 2.0 | 3.5 |
AS 9.6K | 80 | 3500 | 44000 | 2.0 | 3.5 |
Note:
Output specifications mentioned in the table is based on 100 ppm input hardness as CaCO3.
Output between regeneration and max. Flow rate depends on feed water hardness.
Higher capacity plants can be designed and supplied as per specifications.
For AS 600 Model, the vessel is FRP and ball valves are used for service and regeneration.
Applications:
The soft water obtained can be used:
As Feed water to distillers - For longer life of the boiler, to obtain high quality of distillate and to prevent scaling in the boiler, soft water can be used as feed to the boilers.
For Cooling water make-up.
In Laboratories and research institutes
In Food and Beverage production etc.
In Hotels, Hospitals and Laundries.
The New "Interlabs Aqua DM - XL Series" have several User-friendly features and are available in three standard models.
De-Mineralisers(De-ionisers) are based on Ion exchange Technology and removes all the dissolved ions present in the raw water and the demineralised water produced is of High purity, with low electrical conductivity (lesser than 10 microS/cm at 250C).
Note : When the Exchanger (Resin) is exhausted, it has to be regenerated with dil. HCl solution and caustic soda for cation and anion respectively.
Features :
New! User Friendly Features :
Specifications :
Model No. | Min Flow Rate (lit/hr) | Max Flow Rate(lit/hr) | Output bet. Reg.(lit) | Min Pressure (kg/cm2) |
Aqua DM 600/100 A/D | 10 | 100 | 600 | 0.5 |
Aqua DM 2000/200 A/D | 20 | 200 | 2000 | 1.5 |
Aqua DM 3500/600 A/D | 60 | 600 | 3500 | 2.0 |
DM Plants can be used where good quality water of low conductivity is required. In general, Demineralised water can be used for the following:
The new Lab DM 200 is a two bed portable De-ioniser which produces demineralised water that is substantially free from dissolved solids at flow rate up to 10 ltrs per hour. This particular model can be wall mounted / Table top design.
The design of DM 200 is such that the service and regeneration is very simple. This is an ideal model to all laboratories where the usage of DM water is minimal or it can be used as feed to distillers
Interlabs introduces its new domestic water softener that provides good quality soft water for domestic and household use.
Features :
Interlabs Mixed Bed is used to obtain high purity, low conductivity water (<1 microS/cm).
It is used as a polisher unit in series with the De-Mineraliser plant / Reverse Osmosis System.
The charged resin in the Mixed Bed removes all the minerals present in feed water and gives an output having electrical conductivity lesser than 1 microS/cm. The low conductivity water thus obtained can be used for various laboratory and industrial applications where water of high purity is required.
Features:
Note :
When resin is exhausted, it has to be regenerated with caustic soda solution and dilute hydrochloric acid solution respectively.
Specifications :
Model No. | Min. Flow rate(lit/hr) | Max Flow Rate(lit/hr) | Output bet. Reg.(lit) | Min. Pressure(Kg/cm2) | Max. Pressure(Kg/cm2) |
Interlabs MB 1500 | 10 | 60 | 1500 | 0.5 | 2.5 |
Interlabs MB 3000 | 25 | 250 | 3000 | 1.5 | 2.5 |
Interlabs MB 8000 | 60 | 600 | 8000 | 0.5 | 3.5 |
Additional Specifications:
Note:
Applications:
The MixedBed water can be used,
Interlabs Pre-Filters can be used for pre treatment of water for trouble-free operation.
Features
Specifications :
Type | Polypropylene |
Filtration size | 10 microns |
Element size | 25 cm |
Max flow rate | 25 litres/min |
Max working pressure | 100 p.s.i |
Max working temperature | 40 o C |
Connections - inlet | Tap adaptor |
Connections - outlet | 12mm hose spout |
Dimensions | 13 x 31.5 cms |
Material | ABS Blue (Lid & Bowl) |
Disposable Filter Cartridge | Spun-bounded Polypropylene |
Introducing! Interlabs Pure Water Systems for Laboratory applications.
Available in two different models with an output of 10 lit/hr and 20 lit/hr
Interlabs Reverse Osmosis Plants (RO Plants) incorporates the latest R.O Membrane technology to remove and reject a wide spectrum of impurities from water. It improves the quality and taste of drinking water.
The raw water from tap first flows into a 5 micron filter to remove dirt, dust etc., then to a carbon catridge filter which takes out chlorine and organic chemicals. Then to a antiscalant catridge. The filtered water is finally forced through a semi permeable membrane having a pore size of 0.0001 micron size which rejects 95% and above dissolved impurities.
Applications:
Interlabs Sparkle Safe?incorporates the latest RO membrane technology for purification.
IN SPARKLE SAFE SYSTEM
Specifications :
Power Required | 230V AC |
Salt Rejection | 90 - 95% |
Recovery | 10 - 60% |
Pressure | 6 -10 kg/cm 2 |
Capacity: | 10 ltrs/hr |
Applications:
Suitable for Domestic Purposes
Interlabs is proud to add on Water treatment plants to its existing product range. Interlabs Water treatment plants are designed to suit every customer's need.
The products under this category include: