For determining the value of ?g? by measuring the time taken by a falling steel ball. The apparatus consists of a release unit and a trip unit. Both these units size 13x9x1cm are fitted with 4mm sockets and can be readily clamped on to a 12mm diameter rod. The release unit is fitted with a small solenoid type electromagnet which holds a steel ball. The solenoid helps in the prompt release of the ball on being disconnected. The trip unit has a swinging plate and is fitted with a switch. The switch is normally held closed by a magnet and is opened when the ball falls on the plate. The time of fall is measured by a digital Centisecond Timer. Supplied complete with steel balls but without Centisecond Timer, retort stand and base.
-01 Centisecond Timer for ?g? by free fall apparatus.
The set comprises of:
» Faraday's Pail
» Perspex cylinder with suspended metallised sphere
» Head of hair
» Point discharge
» Electric whirl
» Neon Bulb
» Electric Tester
Ammeter D.C.
Moving coil meters. Scale length 60mm approx. with knife edge pointer and anti parallax mirror scale. Size 80x110x80mm. Accuracy ±2% F.S.D.
Single Range | |
-01 | Microammeter, 0-25µA |
-02 | Microammeter, 0-50µA |
-03 | Microammeter, 0-100µA |
-04 | Microammeter, 0-500µA |
-05 | Milliammeter, 0-1mA |
-06 | Milliammeter, 0-10mA |
-07 | Milliammeter, 0-100mA |
-08 | Milliammeter, 0-500mA |
-09 | Ammeter, 0-1A |
-10 | Ammeter, 0-3A |
-11 | Ammeter, 0-5A |
-12 | Ammeter, 0-10A |
Double Range | |
-13 | Ammeter, 0-1A and 0-5A |
Triple Range | |
-14 | Ammeter, 0-50mA, 0-500mA and 0-5A |
Rectifier type. | |
-15 | Milliammeter, 0-1mA |
-16 | Milliammeter, 0-10mA |
-17 | Milliammeter, 0-100mA |
-18 | Milliammeter, 0-500mA |
-19 | Ammeter, 0-1A |
-20 | Ammeter, 0-3A |
-21 | Ammeter, 0-5A |
-22 | Ammeter, 0-10A |
Consist of two painted bar magnets with poles stamped and keepers. Supplied in a handy wooden storage box.
Length :-01 | 50mm |
-02 | 75mm |
-03 | 100mm |
Consist of two painted bar magnets with poles stamped and keepers. Supplied in a handy wooden storage box.
Length :-01 | 50mm |
-02 | 75mm |
-03 | 100mm |
For determination of specific heat capacity of the liquid by electrical method. Consists of an inner vessel 75x50mm diameter, carried on a 100x75mm diameter outer vessel. Fitted with a Bakelite cover with two 4mm sockets which connects to a 6 ohm heating coil having maximum current capacity of 1A. Complete with rubber stopper for holding thermometer (not supplied) and a stirrer.
-01 | Aluminium construction. |
-02 | Copper construction |
Consists of one spun inner vessel 75x50mm diameter, carried on a 100x75mm diameter outer vessel. Felt jacket is provided between the vessels and also at the bottom of the outer vessel for proper insulation. Fitted with a Bakelite cover with two holes. One hole is for rubber stopper which will hold the thermometer and the other hole is for the stirrer. Complete with rubber stopper, stirrer and washer, but without thermometer.
-01 | Aluminium construction. |
-02 | Copper construction. |
Comprising rods of different materials and some of different thickness to enable students to test for themselves different thermal conductivities. Kit comprises:
Category | Diameter (mm) | Qty. |
Aluminium | 3 | 8 |
Glass | 3 | 8 |
Brass | 1.5 & 3 | 8 each |
Copper | 1.5 & 3 | 8 each |
Iron | 1.5 & 3 | 8 each |
Consist of two painted bar magnets with poles stamped and keepers. Supplied in a handy wooden storage box.
Length :-01 | 75mm |
-02 | 100mm |
-03 | 150mm |
Consist of two painted bar magnets with poles stamped and keepers. Supplied in a handy wooden storage box.
Length :-01 | 75mm |
-02 | 100mm |
-03 | 150mm |
One Dial
Consists of one or more dials each consisting of ten-position switch and two 4mm sockets fitted in a metal box. Accuracy ?1%.
-01 10x0.01?F
-02 10x0.1?F
-03 10x1?F
Two Dials
-04 10x0.01?F and 10x0.1?F
-05 10x0.1?F and 10x1?F
Three Dials
-06 10x0.01?F, 10x0.1?F and 10x1?F
Four Dials
-07 10x0.001?F, 10x0.01?F, 10x0.1?F and 10x1?F
A very convenient meter having a clear 3½ digit LCD display. Provided with a control for switching ON and OFF the meter. Fitted with a pair of 4mm sockets. Operates on 9V battery. Accuracy ±2%. Size 80x110x80mm approx. With battery.
Range D.C. Current | |
-01 | 0-200µA |
-02 | 0-2mA |
-03 | 0-20mA |
-04 | 0-200mA |
-05 | 0-2A |
-06 | 0-10A |
Range D.C. Voltage | |
-07 | 0-200mV |
-08 | 0-2V |
-09 | 0-20V |
-10 | 0-200V |
-01 | Glass Rod, 300x12mm |
-02 | Ebonite Rod, 300x12mm |
-03 | Acrylic Rod, 300x12mm |
-04 | Half Brass - Half Glass Rod, 300x12mm |
-05 | Half Brass - Half Ebonite Rod, 300x12mm |
Moving coil meters. Scale length 60mm approx. with knife edge pointer and anti parallax mirror scale. Size 80x110x80mm. Accuracy ±2% F.S.D.
-01 | 3.5mA - 0 - 3.5mA, resistance 10ohm |
-02 | 50µA - 0 - 50µA, resistance 1000ohm |
Steel with keepers. Painted red.
Length :-01 | 50mm |
-02 | 75mm |
-03 | 125mm |
The meter can be used for demonstration of A.C or D.C. ammeter or voltmeter with different interchangeable scales. A magnetically damped, spring-controlled moving coil movement with a pointer, housed in a plastic case with glass front and rear panels enable all working parts to be clearly seen. With a pair of 4mm socket terminals and side zero adjustment control. The scales, 200mm long (approx.) are boldly marked and figured on both sides. Each scale is fitted through a slot in the side of the case and has a plug connector which also serves to locate and align the scale positively in position. Basic sensitivity of the meter is 5mA, 100mV F.S.D. Without scale. Accuracy: ? 2.5%, F.S.D., Scales:
Range D.C. Current | |
-01 | 2.5-0-2.5mA |
-02 | 0-10mA |
-03 | 0-100mA |
-04 | 0-500mA |
-05 | 0-1A |
-06 | 0-5A |
Range A.C. Voltage | |
-07 | 5-0-5V |
-08 | 0-5V |
-09 | 0-10V |
-10 | 0-300V |
Range A.C. Current | |
-11 | 0-10mA |
-12 | 0-50mA |
-13 | 0-100mA |
-14 | 0-500mA |
-15 | 0-1A |
-16 | 0-10A |
Range D.C. Voltage | |
-17 | 0-5V |
-18 | 0-10V |
-19 | 0-50V |
-20 | 0-300V |